Zygossota · Retractor for zygomatic implant surgery
Follow this line.
You don't know what it is… yet.

This curve… is for your hand.
The grip is the 1.5 mm sheet itself, folded into a U. No welds, no seams.

This one, for your thumb.
A shallow saddle on the grip, where the thumb rests and steers.

This one, for the lip.
The domed blade holds the lip the way a Minnesota does.

These two, for the bone.
Two points of support on the bone keep the instrument steady.

And this one… to protect the drill.
The tongue forms a tunnel under the flap. The drill exit stays in view and protected.

One line. From your thumb… to the zygoma.
It holds the lip, rests on the bone and protects the drill exit. One instrument, from one sheet of steel.

Like a Minnesota…but for the zygoma.
The same instrument works on both sides.

Zygossota™
Both legs rest on the zygoma. The tongue slides under the flap and opens the field. Light and irrigation reach the osteotomy, and you see the drill exit instead of guessing.

No two zygomas are alike.
One grip, three working ends. Less trauma in small faces, a proportional view in large ones. The same instrument works on both sides.
Anatomy varies. Studies measure how much.
In anatomical studies of the zygoma, the mean never comes alone: it comes with the standard deviation, the measure of how far one patient is from the next.
For zygoma thickness, one standard deviation is a quarter of the mean: 2.1 mm in 8.0 mm. For bone-to-implant contact, it is more than a third. A single size is too large for some and too small for others.
That is why there are three. The working end is 15.6 mm wide in S, 19.5 mm in M and 23.4 mm in L: one fifth below and one fifth above M, the same order of magnitude as one standard deviation.
- 8.0 ± 2.1 mm
- Zygoma thickness at its thickest point, in 300 zygomata measured on CT.Hung et al., 2017
- 44.3 to 54.3 mm
- Distance from the alveolar crest to the jugale point of the zygoma: the range the authors derive from the mean and standard deviation, in 22 cadaver sides.Uchida et al., 2001
- 15.3 ± 5.6 mm
- Implant length in contact with the zygomatic bone, in 173 implants in 77 patients.Balshi et al., 2012
- Hung KF, Ai QY, Fan SC, Wang F, Huang W, Wu YQ. Measurement of the zygomatic region for the optimal placement of quad zygomatic implants. Clin Implant Dent Relat Res. 2017;19(5):841-848. doi:10.1111/cid.12524
- Uchida Y, Goto M, Katsuki T, Akiyoshi T. Measurement of the maxilla and zygoma as an aid in installing zygomatic implants. J Oral Maxillofac Surg. 2001;59(10):1193-1198. doi:10.1053/joms.2001.26725
- Balshi TJ, Wolfinger GJ, Shuscavage NJ, Balshi SF. Zygomatic bone-to-implant contact in 77 patients with partially or completely edentulous maxillas. J Oral Maxillofac Surg. 2012;70(9):2065-2069. doi:10.1016/j.joms.2012.05.016
The full film, with sound.
Fifty-nine seconds. The same lines, with voice and music.
Be the first to know.
Leave your contact and hear first when Zygossota arrives. Manufactured and sold by Supremo. Patent pending.
Done. You are on the list.
We will let you know when Zygossota launches, by email and WhatsApp.