Sizes
ZYGOSSOTA™Designed by Fernando Giovanella Português

Zygossota · Retractor for zygomatic implant surgery

Follow this line.

You don't know what it is… yet.

A Zygossota curve in steel, so close you can't tell what it is yet

This curve… is for your hand.

The grip is the 1.5 mm sheet itself, folded into a U. No welds, no seams.

The Zygossota grip, the steel sheet itself folded into a U

This one, for your thumb.

A shallow saddle on the grip, where the thumb rests and steers.

The shallow saddle on the Zygossota grip, where the thumb rests

This one, for the lip.

The domed blade holds the lip the way a Minnesota does.

The domed blade of the Zygossota, which holds the lip

These two, for the bone.

Two points of support on the bone keep the instrument steady.

The two Zygossota legs, the points of support on the bone

And this one… to protect the drill.

The tongue forms a tunnel under the flap. The drill exit stays in view and protected.

The Zygossota tongue, which forms a tunnel and protects the drill exit

One line. From your thumb… to the zygoma.

It holds the lip, rests on the bone and protects the drill exit. One instrument, from one sheet of steel.

The whole Zygossota retractor in profile: one line from grip to tip

Like a Minnesota…but for the zygoma.

The same instrument works on both sides.

The Zygossota in profile with the tongue folding back

Zygossota™

Both legs rest on the zygoma. The tongue slides under the flap and opens the field. Light and irrigation reach the osteotomy, and you see the drill exit instead of guessing.

3D image of the instrument on a bone model.
Zygossota seated on the zygomatic bone, grip pointing up

No two zygomas are alike.

One grip, three working ends. Less trauma in small faces, a proportional view in large ones. The same instrument works on both sides.

The three Zygossota sizes side by side: S, M and L
S15.6 mm48.8 g
M19.5 mm51.7 g
L23.4 mm54.7 g
Working-end width and weight, calculated from the 3D model of each size.

Anatomy varies. Studies measure how much.

In anatomical studies of the zygoma, the mean never comes alone: it comes with the standard deviation, the measure of how far one patient is from the next.

For zygoma thickness, one standard deviation is a quarter of the mean: 2.1 mm in 8.0 mm. For bone-to-implant contact, it is more than a third. A single size is too large for some and too small for others.

That is why there are three. The working end is 15.6 mm wide in S, 19.5 mm in M and 23.4 mm in L: one fifth below and one fifth above M, the same order of magnitude as one standard deviation.

S15.6 mmM19.5 mmL23.4 mm-1 SDmean+1 SD
Illustrative curve. Gold band: one standard deviation of zygoma thickness, 26% of the mean (Hung et al., 2017). Marks: the working-end width of each size relative to M.
8.0 ± 2.1 mm
Zygoma thickness at its thickest point, in 300 zygomata measured on CT.Hung et al., 2017
44.3 to 54.3 mm
Distance from the alveolar crest to the jugale point of the zygoma: the range the authors derive from the mean and standard deviation, in 22 cadaver sides.Uchida et al., 2001
15.3 ± 5.6 mm
Implant length in contact with the zygomatic bone, in 173 implants in 77 patients.Balshi et al., 2012
Sources
  1. Hung KF, Ai QY, Fan SC, Wang F, Huang W, Wu YQ. Measurement of the zygomatic region for the optimal placement of quad zygomatic implants. Clin Implant Dent Relat Res. 2017;19(5):841-848. doi:10.1111/cid.12524
  2. Uchida Y, Goto M, Katsuki T, Akiyoshi T. Measurement of the maxilla and zygoma as an aid in installing zygomatic implants. J Oral Maxillofac Surg. 2001;59(10):1193-1198. doi:10.1053/joms.2001.26725
  3. Balshi TJ, Wolfinger GJ, Shuscavage NJ, Balshi SF. Zygomatic bone-to-implant contact in 77 patients with partially or completely edentulous maxillas. J Oral Maxillofac Surg. 2012;70(9):2065-2069. doi:10.1016/j.joms.2012.05.016

The full film, with sound.

Fifty-nine seconds. The same lines, with voice and music.

Be the first to know.

Leave your contact and hear first when Zygossota arrives. Manufactured and sold by Supremo. Patent pending.

You are

Your data stays with Clínica Dr. Fernando Giovanella Ltda., stored with Cloudflare (USA). It is never sold, or handed to Supremo or to course organizers. Privacy notice

Product in launch phase. Sales depend on regulatory clearance by Anvisa (Brazil).